Due to the inherent physical and chemical properties of ozone, the preparation, storage and transportation of standard ozone gas cannot adopt the conventional methods used for other standard gas substances. The "on-site preparation and immediate use" method is mandatory for standard ozone gas, which increases the difficulty in its preparation and storage. The HR-OSS-500 Ozone Standard Generator addresses this challenge effectively by utilizing high-precision mass flow meters for accurate gas ratio control and advanced PID algorithms. It allows users to set any concentration within the range of 1-500 PPM, featuring large output flow, rapid response, excellent stability and repeatability. The generator delivers accurate and stable standard ozone gas, with overall performance reaching an internationally advanced level. It is widely applicable for the verification, calibration and testing of ozone analytical instruments.
Features:
1. Adopts a new semiconductor nano-process ultra-low power consumption 32-bit microprocessor.
2. Utilizes complex PID algorithms for precise control.
3. Large ozone output flow, capable of meeting high-flow demand.
4. Equipped with ultra-pure ceramic ozone generating tubes, featuring long service life and high conversion efficiency.
5. Uses imported UV light sources with stable performance and long lifespan.
6. No need for oxygen source as consumables for ozone generation.
7. Built-in catalytic decomposition device for excess ozone to reduce air pollution.
8. Equipped with overvoltage protection, overcurrent protection, anti-static interference, anti-magnetic field interference and other functions.
|
Calibration Gas: |
Ozone(O3) |
Calibration Range: |
1-500PPM(umol/mol) |
|
Max allowable error: |
≤5% |
Repeatability: |
≤2% |
|
Linearity: |
R2>0.999 |
Response time: |
≤5Min |
|
Resolution: |
0.01PPM |
Interface size: |
4×6mm |
|
Output gas flow: |
>7L/Min |
Detector Inhalation Volume: |
<3L/Min |
|
External zero air requirements: |
Flow >30L/Min, pressure 0.2Mpa, temperature 10~35℃ (fluctuation ≤2℃; optional air source is available if the customer lacks a qualified gas supply) |
||
|
Operating Environment: |
T: 10~35℃,RH:≤85%,Normal pressure |
||
|
Power supply: |
AC220V±10%,50Hz |
||
|
Dimension & Weight : |
600×600×1166 mm(L×W×H),120KG |
||
|
Standard accessories: |